Ultrasonic Thickness Gauge TIME®2190 with A/B scan
TIME®2190 is the latest high-end ultrasonic thickness gauge developed by TIME Group Inc. It adopts pulse reflection principle, that is, the transducer sends ultrasonic pulses to travel through the test object and receives the reflection pulse from the backwall of the object. TIME2190 can nondestructively monitor the thickness of almost any material like metals, plastics, composites, fiberglass, ceramics, and glass with A scan/B scan. It is used to test the wall thickness and corrosion of various kinds of plates, pipes, boilers, vessels across industries like metallurgy, shipbuilding, machinery, chemical, aerospace, power, automotive, oil and gas, manufacturing and others.
Features
⚫ A-scan waveform can be displayed for echo analysis and measurement of complex workpiece;
⚫ Compatible with many types of transducers, both single and dual element transducers;
⚫ Users can set blanks to shield aftershocks or clutter;
⚫ Echo-echo measures the true metal thickness with ignoring the thickness of coating layer.
⚫ Thru-coat technology measures metal and nonmetallic coating thickness.
⚫ Signal auto-amplification function (centered display of the detected echo);
⚫ Adjustable voltage variable pulse width square wave pulse generator;
⚫ Single value B-scan display function;
⚫ Users can turn on fast measurement mode up to 20 times per second;
⚫ Alarm function allows users to set the upper and lower limits of the alarm;
⚫ Differential, maximum and minimum display mode;
⚫ Store up to 500,000 measured values and waveforms.
⚫ A-scan waveform can be displayed for echo analysis and measurement of complex workpiece;
⚫ Compatible with many types of transducers, both single and dual element transducers;
⚫ Users can set blanks to shield aftershocks or clutter;
⚫ Echo-echo measures the true metal thickness with ignoring the thickness of coating layer.
⚫ Thru-coat technology measures metal and nonmetallic coating thickness.
⚫ Signal auto-amplification function (centered display of the detected echo);
⚫ Adjustable voltage variable pulse width square wave pulse generator;
⚫ Single value B-scan display function;
⚫ Users can turn on fast measurement mode up to 20 times per second;
⚫ Alarm function allows users to set the upper and lower limits of the alarm;
⚫ Differential, maximum and minimum display mode;
⚫ Store up to 500,000 measured values and waveforms.
Technical Parameters
Measurement range | 0.20~508mm (depend on probe) |
Velocity range | 508m/s~18699m/s |
Display screen | Color TFT LCD, 320×240 pixels |
Pulse generator | Adjustable Square Wave Pulse Generator |
Resolution | 0.001mm or 0.01 or 0.1mm optional |
Emission voltage | 60V, 110V, 150V, 200V optional |
Emission pulse width | varies with transducer frequency |
Gain range | 0-99dB, 1dB step |
Frequency range | 0.5 Mhz~20Mhz |
Measurement rate | standard (4Hz), fast (20Hz) |
Transducer settings | 10 sets of fixed transducer setting and 22 sets of custom transducer setting |
Data Storage | 500 data files, each capable of storing 1000 measurements and waveforms |
Working temperature | 0°C~40° |
Power | three AA battery or NiMH batteries |
Dimensions (mm) | 187mm×87 mm×43 mm |
Weight (g) | 360g |
Standard Delivery | Optional Accessory | |
Main unit | 1 | Communication cable |
5MHz dual crystal probe | 1 | Standard test block |
Couplant | 1 | Probes |
AA battery | 3 | |
TIME certificate | 1 | |
Warranty card | 1 | |
Instruction manual | 1 |
Applications